Key Consideration in the Construction of Endocrown Restorations: A Review
DOI:
https://doi.org/10.24191/cos.v12i2.4273Keywords:
endocrown restoration, CAD/CAM, endodontically treated teeth, endocrown construction, monoblock restorationAbstract
As a method of tooth restoration, endocrowns have acquired popularity in recent years. Endocrown is one of the treatment options recommended after endodontic treatment. Endodontically treated teeth are more prone to crown failure compared to healthy teeth. This results from its biomechanical preparation. Recent advancements in restorative materials, such as adhesive systems, have reduced the requirement for post-core restoration in endodontically treated teeth. A monoblock ceramic crown is bonded to the remaining tooth structure to provide both functional and aesthetic benefits. This literature review intends to offer a comprehensive summary of the endocrown construction. It focuses on the advantages of endocrown restoration, including the preservation of dental structure and its aesthetic outcomes. This review also highlights the importance of tooth selection, tooth preparation, adhesive techniques, and contraindications in attaining optimal clinical outcomes and long-term restoration success. Endocrowns are a reliable alternative to conventional restorative options, provided that clinicians adhere to the prerequisites and indications outlined for this procedure.References
Atash, R., Arab, M., Duterme, H., & Cetik, S. (2017). Comparison of resistance to fracture between three types of permanent restorations subjected to shear force: An in vitro study. Journal of Indian Prosthodontist Society, 17(3), 239–249. https://doi.org/10.4103/jips.jips_24_17.
Awada, A., & Nathanson, D. (2015). Mechanical properties of resin-ceramic CAD/CAM restorative materials Presented at the American Association of Dental Research/Canadian Association of Dental Research Annual Meeting, Charlotte, NC, March 2014. Journal of Prosthetic Dentistry, 114(4), 587–593. https://doi.org/10.1016/j.prosdent.2015.04.016.
Badr, A., Abozaid, A. A., Wahsh, M. M., & Morsy, T. S. (2021). Fracture resistance of anterior CAD/CAM nanoceramic resin endocrowns with different preparation designs. Brazilian Dental Science, 24(3). https://doi.org/10.14295/bds.2021.v24i3.2384.
Bankoğlu Güngör, M., Turhan Bal, B., Yilmaz, H., Aydin, C., & Karakoca Nemli, S. (2017). Fracture strength of CAD/CAM fabricated lithium disilicate and resin nano ceramic restorations used for endodontically treated teeth. Dental Materials Journal, 36(2), 135–141. https://doi.org/10.4012/dmj.2016-017.
Biacchi, G. R., & Basting, R. T. (2012). Comparison of fracture strength of endocrowns and glass fiber post-retained conventional crowns. Operative Dentistry, 37(2), 130–136. https://doi.org/10.2341/11-105-L.
Dartora, N. R., de Conto Ferreira, M. B., Moris, I. C. M., Brazão, E. H., Spazin, A. O., Sousa-Neto, M. D., Silva-Sousa, Y. T., & Gomes, E. A. (2018). Effect of Intracoronal Depth of Teeth Restored with Endocrowns on Fracture Resistance: In Vitro and 3-dimensional Finite Element Analysis. Journal of Endodontics, 44(7), 1179–1185. https://doi.org/10.1016/j.joen.2018.04.008.
Dash, S., Jena, D., Govind, S., Prasad Jena, S., Ranjan Singh, N., & Lecturer, S. (2020). Endocrowns: A Comprehensive Review. In 8360 Indian Journal of Forensic Medicine & Toxicology (Vol. 14, Issue 4).
de Carvalho, M. A., Lazari, P. C., Gresnigt, M., Del Bel Cury, A. A., & Magne, P. (2018). Current options concerning the endodontically-treated teeth restoration with the adhesive approach. In Brazilian Oral Research (Vol. 32, pp. 147–158). Sociedade Brasileira de Hematologia e Hemoterapia. https://doi.org/10.1590/1807-3107bor-2018.vol32.0074.
De Munck, J., Mine, A., Poitevin, A., Van Ende, A., Cardoso, M. V., Van Landuyt, K. L., Peumans, M., & Van Meerbeek, B. (2012). Meta-analytical review of parameters involved in dentin bonding. In Journal of Dental Research (Vol. 91, Issue 4, pp. 351–357). https://doi.org/10.1177/0022034511431251.
Dejak, B., & Młotkowski, A. (2018). Strength comparison of anterior teeth restored with ceramic endocrowns vs custom-made post and cores. Journal of Prosthodontic Research, 62(2), 171–176. https://doi.org/10.1016/j.jpor.2017.08.005.
Dietschi D, Duc O, & Krejci I. (2007). Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature—part 1. Composition and micro- and macrostructure alterations.
Dogui, H., Abdelmalek, F., Amor, A., & Douki, N. (2018). Endocrown: An Alternative Approach for Restoring Endodontically Treated Molars with Large Coronal Destruction. Case Reports in Dentistry, 2018. https://doi.org/10.1155/2018/1581952.
Einhorn, M., DuVall, N., Wajdowicz, M., Brewster, J., & Roberts, H. (2017). Preparation Ferrule Design Effect on Endocrown Failure Resistance. Journal of Prosthodontics, 28(1), e237–e242. https://doi.org/10.1111/jopr.12671.
Elagra, M. E. (2019). Endocrown preparation: Review. ~ 253 ~ International Journal of Applied Dental Sciences, 5(1), 253–256. www.oraljournal.com.
El-Damanhoury, H. M., Haj-Ali, R. N., & Platt, J. A. (2015). Fracture resistance and microleakage of endocrowns utilizing three cad-cam blocks. Operative Dentistry, 40(2), 201–210. https://doi.org/10.2341/13-143-L.
Fages, M., & Bennasar, B. (2013). The Endocrown: A Different Type of All-Ceramic Reconstruction for Molars. In Article in Journal (Canadian Dental Association. https://www.researchgate.net/publication/259205029.
Fokkinga, W. A., Kreulen, C. M., Le Bell-Rçnnlçf, A.-M., Lassila, L. V. J., Vallittu, P. K., & Creugers, N. H. J. (2006). In vitro fracture behavior of maxillary premolars with metal crowns and several post-and-core systems.
Ghajghouj, O., & Taşar-Faruk, S. (2019). Evaluation of fracture resistance and microleakage of endocrowns with different intracoronal depths and restorative materials luted with various resin cements. Materials, 12(16). https://doi.org/10.3390/ma12162528.
Giannini, M., Takagaki, T., Bacelar-Sá, R., Vermelho, P. M., Ambrosano, G. M. B., Sadr, A., Nikaido, T., & Tagami, J. (2015). Influence of resin coating on bond strength of self-adhesive resin cements to dentin. Dental Materials Journal, 34(6), 822–827. https://doi.org/10.4012/dmj.2015-099.
Gregor, L., Bouillaguet, S., Onisor, I., Ardu, S., Krejci, I., & Rocca, G. T. (2014). Microhardness of light- and dual-polymerizable luting resins polymerized through 7.5-mm-thick endocrowns. Journal of Prosthetic Dentistry, 112(4), 942–948. https://doi.org/10.1016/j.prosdent.2014.02.008.
Hussain, S. K. F., McDonald, A., & Moles. David R. (2007). In vitro study investigating the mass of tooth structure removed following endodontic and restorative procedures.
Imen, D. (2018). “ENDOCROWN”: A Reliable Alternative to Restorate RCT Molar! – Two Case Reports. Advances in Dentistry & Oral Health, 9(5). https://doi.org/10.19080/adoh.2018.09.555774.
Juloski, J., Radovic, I., Goracci, C., Vulicevic, Z. R., & Ferrari, M. (2012). Ferrule effect: A literature review. In Journal of Endodontics (Vol. 38, Issue 1, pp. 11–19). https://doi.org/10.1016/j.joen.2011.09.024.
Kameyama, A., Bonroy, K., Elsen, C., Lührs, A. K., Suyama, Y., Peumans, M., Van Meerbeek, B., & De Munck, J. (2015). Luting of CAD/CAM ceramic inlays: Direct composite versus dual-cure luting cement. Bio-Medical Materials and Engineering, 25(3), 279–288. https://doi.org/10.3233/BME-151274.
Kanat-Ertürk, B., Saridağ, S., Köseler, E., Helvacioğlu-Yiğit, D., Avcu, E., & Yildiran-Avcu, Y. (2018). Fracture strengths of endocrown restorations fabricated with different preparation depths and CAD/CAM materials. Dental Materials Journal, 37(2), 256–265. https://doi.org/10.4012/dmj.2017-035.
Magne, P., Carvalho, A. O., Bruzi, G., Anderson, R. E., Maia, H. P., & Giannini, M. (2014). Influence of no-ferrule and no-post buildup design on the fatigue resistance of endodontically treated molars restored with resin nanoceramic CAD/CAM crowns. Operative Dentistry, 39(6), 595–602. https://doi.org/10.2341/13-004-L.
Magne, P., Schlichting, L. H., Maia, H. P., & Baratieri, L. N. (2010). In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneers. Journal of Prosthetic Dentistry, 104(3), 149–157. https://doi.org/10.1016/S0022-3913(10)60111-4.
Marchionatti, A. M. E., Valli, V., Wandscher, V. F., Monaco, C., & Baldissara, P. (2017). Influence of elastic modulus of intraradicular posts on the fracture load of roots restored with full crowns. Revista de Odontologia Da UNESP, 46(4), 232–237. https://doi.org/10.1590/1807-2577.01617.
Mjör, I. A., Smith, M. R., Ferrari, M., & Mannocci, F. (2001). The structure of dentine in the apical region of human teeth. In International Endodontic Journal (Vol. 34).
Morris, H. F. (1989). Veterans Administration Cooperative Studies Project No. 147/242. Part VII: The mechanical properties of metal ceramic alloys as cast and after simulated porcelain firing.
Müller, J. A., Rohr, N., & Fischer, J. (2017). Evaluation of ISO 4049: water sorption and water solubility of resin cements. European Journal of Oral Sciences, 125(2), 141–150. https://doi.org/10.1111/eos.12339.
Nelson, S. J., & Ash Jr, M. M. (2010). Wheeler’s Dental Anatomy, Physiology, and Occlusion.
Nikaido, T., Tagami, J., Yatani, H., Ohkubo, C., Nihei, T., Koizumi, H., Maseki, T., Nishiyama, Y., Takigawa, T., & Tsubota, Y. (2018). Concept and clinical application of the resin-coating technique for indirect restorations. In Dental Materials Journal (Vol. 37, Issue 2, pp. 192–196). Japanese Society for Dental Materials and Devices. https://doi.org/10.4012/dmj.2017-253.
Politano, G., Van Meerbeek, B., & Peumans, M. (2018). Nonretentive Bonded Ceramic Partial Crowns: Concept and Simplified Protocol for Long-lasting Dental Restorations. The Journal of Adhesive Dentistry, 20(6), 495–510. https://doi.org/10.3290/j.jad.a41630.
Rocca, G. T., Daher, R., Saratti, C. M., Sedlacek, R., Suchy, T., Feilzer, A. J., & Krejci, I. (2017). Restoration of severely damaged endodontically treated premolars: The influence of the endo-core length on marginal integrity and fatigue resistance of lithium disilicate CAD-CAM ceramic endocrowns. Journal of Dentistry, 68, 41–50. https://doi.org/10.1016/j.jdent.2017.10.011.
Rocca, G. T., Saratti, C. M., Poncet, A., Feilzer, A. J., & Krejci, I. (2016). The influence of FRCs reinforcement on marginal adaptation of CAD/CAM composite resin endocrowns after simulated fatigue loading. Odontology, 104(2), 220–232. https://doi.org/10.1007/s10266-015-0202-9.
Sano, H., Ciucchi, B., & Matthews, W. G. (1994). Tensile Properties of Mineralized and Demineralized Human and Bovine Dentin. Journal of Dental Research, 73(6), 1205–1211. https://doi.org/10.1177/00220345940730061201.
Sarr, M., Mine, A., de Munck, J., Cardoso, M. V., Kane, A. W., Vreven, J., van Meerbeek, B., & van Landuyt, K. L. (2010). Immediate bonding effectiveness of contemporary composite cements to dentin. Clinical Oral Investigations, 14(5), 569–577. https://doi.org/10.1007/s00784-009-0327-8.
Schwartz, R. S., & Robbins, J. W. (2004). Post Placement and Restoration of Endodontically Treated Teeth: A Literature Review.
Sedrez-Porto, J. A., Rosa, W. L. de O. da, da Silva, A. F., Münchow, E. A., & Pereira-Cenci, T. (2016). Endocrown restorations: A systematic review and meta-analysis. In Journal of Dentistry (Vol. 52, pp. 8–14). Elsevier Ltd. https://doi.org/10.1016/j.jdent.2016.07.005.
Skupien, J. A., Luz, M. S., & Pereira-Cenci, T. (2016). Ferrule effect: A meta-analysis. In JDR Clinical and Translational Research (Vol. 1, Issue 1, pp. 31–39). SAGE Publications Ltd. https://doi.org/10.1177/2380084416636606.
Sorensen, J. A., & Engelman, M. J. (1990). Effect of post adaptation on fracture resistance of endodontically treated teeth.
Taha, D., Spintzyk, S., Schille, C., Sabet, A., Wahsh, M., Salah, T., & Geis-Gerstorfer, J. (2017). Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness. Journal of Prosthodontic Research, 62(3), 293–297. https://doi.org/10.1016/j.jpor.2017.11.003.
Tay, F. R., & Pashley, D. H. (2007). Monoblocks in Root Canals: A Hypothetical or a Tangible Goal. Journal of Endodontics, 33(4), 391–398. https://doi.org/10.1016/j.joen.2006.10.009.
Thomas, R. M., Kelly, A., Tagiyeva, N., & Kanagasingam, S. (2020). Comparing endocrown restorations on permanent molars and premolars: a systematic review and meta-analysis. British Dental Journal. https://doi.org/10.1038/s41415-020-2279-y.
Trajtenberg, C. P., Caram, S. J., & Kiat-Amnuay, S. (2008). Microleakage of all-ceramic crowns using self-etching resin luting agents. Operative Dentistry, 33(4), 392–399. https://doi.org/10.2341/07-101.
Udo, T., Nikaido, T., Ikeda, M., Weerasinghe, D. S., Harada, N., Foxton, R. M., & Tagami, J. (2007). Enhancement of Adhesion between Resin Coating Materials and Resin Cements. Dental Materials Journal.
Waaz, S. (2020). Impact of Preparation Depth and Length on Fracture Resistance of Anterior Teeth Restored by Endocrowns and Post Retained Crowns. Egyptian Dental Journal, 66(1), 507–516. https://doi.org/10.21608/edj.2020.79126.
Zarone, F., Sorrentino, R., Apicella, D., Valentino, B., Ferrari, M., Aversa, R., & Apicella, A. (2006). Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a natural tooth: A 3D static linear finite elements analysis. Dental Materials, 22(11), 1035–1044. https://doi.org/10.1016/j.dental.2005.11.034.
Zhu, J., Rong, Q., Wang, X., & Gao, X. (2017). Influence of remaining tooth structure and restorative material type on stress distribution in endodontically treated maxillary premolars: A finite element analysis. Journal of Prosthetic Dentistry, 117(5), 646–655. https://doi.org/10.1016/j.prosdent.2016.08.023.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Compendium of Oral Science

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Materials contained in the journal may be reproduced for educational purposes provided that both the author(s) and the journal are appropriately recognised; otherwise duplication is not permitted. No articles, reports, or portions there of may be translated into other languages, published in books, journals, magazines, or any other print form without written permission from the authors and from the journal.
Disclaimer: The statements, opinions and data expressed in the articles and reports herein are those of the author(s) and not of the publisher and the editor(s). The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any schemes, methods, instructions or ideas referred to in the content.








